beautypg.com

Roland PCR-1 User Manual

Page 113

background image

113

Troubleshooting

* Depending on your system, a

DMA Settings

dialog box may appear. Check the contents, and click

either

[OK]

or

[Cancel]

.

6.

In the

System Properties

dialog box, click

[OK]

to close the dialog box. Then restart your

computer.

Try installing more memory.

Installing more memory will increase the performance of your computer. For details on how to
install more memory, refer to the operation manual for your computer.

Does your computer satisfy the requirements of the USB standard?

If you are using a computer (such as a computer that you yourself assembled) that does not satisfy
the electrical requirements of the USB specifications, you may experience interruptions in the
audio. If this occurs, you may be able to solve the problem by connecting a USB hub that contains
its own power supply.

In some cases you may be able to solve this problem in the “EDIROL PCR-1 Driver
settings” dialog box.

For details, refer to the section

“Part of the playbacks wrong: e.g., notesare broken

offprematurely, or somenotes are lost”

within the

README_E

file located in the folder in which

you installed the CD-ROM.

On some computers, audio playback may be interrupted due to the Power Management
settings in the Control Panel.

The Power Supply Properties that you see when you double-click

Power Management

will differ

depending on your computer system. One example is given below, but you should also refer to the
operation manual for your computer. Some computers may not have all of the following setting
items.

1.

Click the Windows Start button, and select

Settings | Control Panel

to open the

[Control

Panel]

.

2.

In

Control Panel

, double-click

System

to open the

System Properties

dialog box.

3.

Click the

Device Manager

tab.

4.

Double-click

System Devices

to display the

list of devices

.

5.

From the list, select

Advanced Power Management Support

. Then click

Properties

to open

the

Advanced Power Management Support Properties

dialog box.

6.

Click the

Settings

tab, and in

Troubleshooting

, place a check in the check box for

Don’t Poll

Power Supply Status

. Then click

[OK]

.

7.

In the System Properties dialog box, click

[OK]

.

8.

Restart Windows.

PCR-1_e1.book 113 ページ 2003年11月20日 木曜日 午後3時22分