RuggedBackbone™ RX1510

Installation Guide

Chapter 3

Installation

SFP Optics – Installation, removal, and precautions

27

Table 11: DDS Tx LED Indications

Tx LED Color

Status

GREEN

The interface is enabled and remote device has no errors.

YELLOW

The interface is in loopback mode.

RED

Loss of signal or receiving any of OOS, UNM, or UMC codes: the remote device is out of service or has

problems with the signal.

OFF

The interface is not enabled.

Section 3.11

SFP Optics – Installation, removal, and precautions

The RX1510 can be ordered with SFP (Small Form-factor Pluggable) pluggable optics modules. SFP modules

can be safely inserted and removed while the chassis is powered and operating. When inserting or removing

optics, observe the following precautions:
• Ensure that dust caps are mounted on SFP cages at all times, unless you are in the process of inserting or

removing an SFP module. The dust caps prevent the accumulation of residue or particles that might inhibit

proper operation.

• Ensure that you have properly discharged any possible electrostatic build-up to prevent electrostatic

discharges (ESD). This can be accomplished by proper grounding through an ESD wrist strap, or by touching

earth or chassis ground before installing or removing optical modules. ESD can damage or shorten the life of

optical modules when they are not plugged into a chassis.

• Ensure that SFP optical modules are always stored in an ESD-safe bag or other suitable ESD-safe

environment. Keep SFP modules free from moisture and store them at the proper temperature (-40°C to

+85°C).

• Disconnect all cables from the SFP module before inserting or removing the module.
• Use only components certified by RuggedCom Inc. with RuggedCom products. Damage can occur to optics

and product if compatibility and reliability have not been properly assessed.

Section 3.11.1

Module Insertion – SFP

Special attention must be paid to the orientation of SFP modules upon installation in the RX1510 chassis. The

figure below shows the proper orientation of SFP modules installed in both upper and lower line modules. SFP

modules on the upper row must be inserted top-side up. SFP modules on the lower row must be inserted top-side

down. SFP modules should be inserted with the bail-latch in the locked position.