Page 54 of 83

2.8 Analog Port Input Control Circuit

The analog port input control circuit is used to control the status of the M32R/ECU ports AD0IN0
and AD0IN1 by using VR controls VOL0 and VOL1.

U1
M32R/ECU

AVCC

AD0IN0

H3

1 2

H4

1 2

AVCC

VOL0

VOL1

AD0IN1


Figure 2.9 Analog Port Input Control Circuit

Table 2.12 Analog Port Input Control (Jumper)

Name Default Condition

Description

{

Shorted

between 1–2

Uses VR control (VOL0)

H3

Open

between 1–2

Does not use VR control (VOL0)

{

Shorted

between 1–2

Uses VR control (VOL1)

H4

Open

between 1–2

Does not use VR control (VOL1)

Note: The H3 and H4 jumpers are shorted by soldering.