Page 15 of 83

5.2.3 M3A-2152 Evaluation Board Power Supply and Settings

The following shows how to set the M3A-2152 Evaluation Board.
Use a 5V DC power supply to feed power to the M3A-2152 Evaluation Board.
Use included 5V power supply cable to connect the 5V DC power supply and CN2 connector
included with the M3A-2152 Evaluation Board. The Connecting when Feeding Power to the
M3A-2152 Evaluation Board is shown in Figure 5.6.





Figure 5.6 Connecting when Feeding Power to the M3A-2152 Evaluation Board

Table 5.4 Jumper Settings before Shipmen

Jumper Name

Jumper Settings

Remarks

H1

Shorted between 1-2

Uses power from CN2 connector to AVCC power supply

Note: For detail about the power supply settings, refer to Appendix 3 M3A-2152G02 Product Standards

5.2.4 Connecting M3A-2152 Evaluation Board and M3A-2195

Use included 10-pin Flat cable to connect M3A-2195 and XCN1 connector included with the
M3A-2152 Evaluation Board.
The Connecting M3A-2152 Evaluation Board and M3 is shown in Figure 5.7.





Figure 5.7 Connecting M3A-2152 Evaluation Board and M3A-2195

5.2.5 System Power-on Sequence when M3A-2152G52 in Use

-

When turning on power, turn on M3A-2195 first and then the M3A-2152 Evaluation Board, or
simultaneously.

-

When turning off power, turn off the M3A-2152 Evaluation Board first and then M3A-2195, or
simultaneously.

-

When turning on power again after turning off power, wait for 2 seconds.

Note: Unless the Starter Kit is powered on this sequence, the kit may operate erratically or break down.

M3A-2152 evaluation board

XCN1

10-pin flat cable

M3A-2195

JTAG

4.75 - 5.25V DC power supply

M3A-2152 evaluation board

CN2

H1

This manual is related to the following products: