beautypg.com

3 connecting the m30200t-rpd-e, Caution, When connecting pod probe – Renesas M30220TF-PRB User Manual

Page 23

background image

( 21 / 54 )

Figure 3.4 Removing pod probe M30220TF-PRB

(1) Unscrew the two screws of the M30220TF-PRB.

(2) Remove the M30220TF-PRB from the FLX64-PRB. In

this time, lift off the M30220TF-PRB horizontally.
Otherwise, the connector may cause a break.

CAUTION

When Connecting Pod Probe:

• Be sure to turn off the power before making connections. Otherwise, the internal

circuits may be damaged.

• The small connectors of the M30220TF-PRB (J3 and J4) are guaranteed for only 50

insertion/removal iterations.

• The small connectors of the FLX64-PRB (J3 and J4) and M30220TF-PRB (J1 and

J2) are guaranteed for only 50 insertion/removal iterations.

3.3 Connecting the M30200T-RPD-E

The emulation pod for flash memory rewrite mode debug of the M30220 and M30221 Group MCUs
consists of the two products, the M30200T-RPD-E emulation pod main unit and the M30220TF-PRB
pod probe. Figures 3.3 and 3.4 show how to connect the M30220TF-PRB and how to remove it,
respectively.

Figure 3.3 Connecting pod probe M30220TF-PRB

(1) Connect the J1 and J2 connectors of the M30220TF-

PRB to the J3 and J4 connectors of the FLX64-PRB.

(2) Fix the FLX64-PRB by the two screws.