beautypg.com

Status indicator led descriptions – NEC MC2400 User Manual

Page 44

background image

2-12 Setting Up the System

Status Indicator LED Descriptions

The following tables list the System Status Indicator LEDs, the Disk Drive
Status Indicator LEDs, the Disk Drive Status Abnormal Conditions, the Power
Supply Status Indicator LEDs, and the LAN Status Indicator LEDs along with a
description of each LED indicator.

Front System Status Indicator LEDs

LED

Status

Description

Response

DC Power ON/OFF

Off

DC power OFF

None required (normal)

ON (Green)

DC power ON

None required (normal)

Power Alarm

1

Off

Not active

None required (normal)

ON (Amber)

Failure has occurred in one or more
power supplies (see the "Power Supply
Status Indicators" table DC Power Status
"Amber" that follows.)

Fan Alarm

Off

All fans operating normally

None required (normal)

ON (Amber)

Fan failure

Replace fan in chassis or
replace power supply

Array Alarm

Off

Always OFF unless RAID is installed

None required (normal)

ON (Amber)

RAID Array failure

Replace disk drive with
amber light lite

1

Valid only when a second power supply is installed.

Note:

The Power Supply Status Indicator LEDs are

present only when a second power supply is installed.

Power Supply Status Indicator LEDs (Rear Panel)

LED

Status

Description

Response

Power Supply Status

Off

AC Power not available

None required (normal)

ON (Green)

AC Power supplied to power supply

None required (normal)

DC Power Status*

Off

No alarms

None required (normal)

(Amber)

AC Power disconnected or power supply
failed

Verify AC power is ON,
reconnect AC power, or
replace power supply,

*Connects to the Power Alarm light.