RTU

-292 Operations Manual

Table 2-12

Local Phone Enable

SW1-7 Local

Phone

Off

Disabled

On Enabled

Table 2-13

Local Phone Ringthrough

SW1-8 Ringthrough

Off

Disabled *

On Enabled

2.8.15 TRANSMIT LEVEL SET-UP MODE
Dipswitch SW2-7 is used by the factory to enable a special set-up mode. See section 2.10 for
instructions. This switch must remain Off (Normal Mode) for standard operation.

Table 2-14

TX Level Set-up Mode

SW2-7 Set-up

Mode

Off

Disabled *

On Enabled

2.8.16 MISCELLANEOUS JUMPERS
The following jumpers are installed in the factory as required. This explanation is provided in
case they are accidentally removed and must be replaced.
Security Option Jumpers on J5. Unless a Security Option Interface Cable is plugged into J5 on
the Main Board, jumper plugs must be installed at J5 pins 4&5 and pins 7&8.
Option Jumpers on J10. If the Option tray is not installed, a jumper must be placed at pins
13&14 of J10. This jumper allows normal operation of the unit when the Options Tray and the
Options Interface Board are not installed.

2.9 INTERCONNECT INFORMATION

Interconnect cables should be shielded for best performance. Figure 2.6, Interface Details,
gives simplified interconnect information about the unit.