beautypg.com

Control commands via lan, Technical information, English – Panasonic PT-EW630U User Manual

Page 101: Connection method, Command transmission method

background image

Technical Information

Appendix

ENGLISH -

101

Control commands via LAN

When WEB Control administrator rights password is set (Protect mode)

J

Connection method

z

Obtain the IP address and port number (Initial set value = 1 024) of the projector and

1 )

make a request for connection to the projector.

Acquire the IP address from the menu screen of the projector, and the port number from the WEB control

page.
IP address : Obtain from MAIN MENU → [Network] → [Network status]

Port No. :

Acquire from the WEB control “Detailed set up ” → “Command port set up” page

There is a response from the projector.

2 )

Response data

Data section

Blank

Mode

Blank

Random number

section

Termination

symbol

“NTCONTROL”

(ASCII string)

‘ ’

0x20

‘1’

0x31

‘ ’

0x20

“zzzzzzzz”

(ASCII code hexadecimal

number)

(CR)

0x0d

9 bytes

1 byte

1 byte

1 byte

8 bytes

1 byte

Mode : 1 = Protect mode

Generate a 32-byte hash value from the following data using MD5 algorithm.

3 )

“xxxxxx:yyyyy:zzzzzzzz”

xxxxxx :

Administrator rights user name for WEB CONTROL (Default user name is “admin1”)

yyyyy :

Password of above administrator rights user (Default password is “panasonic”)

zzzzzzzz :

8-byte random number obtained in Step 2

Command transmission method

z

Transmit using the following command format.
Transmitted data

Header

Data section

Termination symbol

Hash value

(See above

)

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

32 bytes

1 byte

1 byte

Undefined length

1 byte

Receive data

Header

Data section

Termination symbol

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

1 byte

1 byte

Undefined length

1 byte

Error response

Error message

Termination symbol

“ERR1”

“ERR2”

“ERR3”

“ERR4”

“ERR5”

“ERRA”

Undefined control command

Out of parameter range

Busy state or no-acceptable period

Timeout or no-acceptable period

Wrong data length

Password mismatch

(CR)

0x0d

4 bytes

1 byte

This manual is related to the following products: