BLANK ALL ABOVE/BLANK ALL BELOW
The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are
ideal for applications where a complete pan location needs to be blanked.
Table C. Window Blank Settings
Figure 3. Window Blank Tilt Angles
Blank All Above
Blank All Below
Tilt Angle
Blanked Area
Tilt Angle
Blanked Area
OFF
No blanking
OFF
No blanking
0
Horizon to 3° above horizon
0
Horizon to 92° below horizon
-10
3° above horizon to 10° below horizon
-10
10° to 92° below horizon
-20
3° above horizon to 20° below horizon
-20
20° to 92° below horizon
-30
3° above horizon to 30° below horizon
-30
30° to 92° below horizon
-40
3° above horizon to 40° below horizon
-40
40° to 92° below horizon
-50
3° above horizon to 50° below horizon
-50
50° to 92° below horizon
-60
3° above horizon to 60° below horizon
-60
60° to 92° below horizon
-70
3° above horizon to 70° below horizon
-70
70° to 92° below horizon
-80
3° above horizon to 80° below horizon
-80
80° to 92° below horizon
10
50
30
80
70
40
20
60
CAMERA
HORIZON