Scan speed, Preset freeze frame, Scan speed preset freeze frame – Pelco SPECTRA C3412M-D User Manual
Page 52

52
C3412M-D (12/08)
SCAN SPEED
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is
adjustable from 1 to 40 degrees per second through the programming menu. The default setting
is 25 degrees per second.
PRESET FREEZE FRAME
This feature freezes the scene on the monitor when going to a preset. This allows for smooth
transition from one preset scene to another. Preset freeze frame also reduces bandwidth when
used with digital network systems such as PelcoNet
™
and guarantees that blanked areas will not
be revealed when going to a preset.
There are three preset freeze frame settings:
ON: The image on the screen freezes when a preset is called. When the dome reaches the
preset, the image is unfrozen and the preset scene is displayed.
OFF: The image is never frozen.
AUTO (default): Freeze frame is turned on automatically if window blanking is ON. If window
blanking is OFF, freeze frame is off.
EXIT
SPECTRA IV
LANGUAGE
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
DOME SETTINGS
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK
ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
* This setting applies only to Pressurized Spectra IV dome systems.