beautypg.com

Dte interface – Paradyne 3821PLUS User Manual

Page 41

background image

COMSPHERE 3821Plus Modem

3-18

February 1998

3821-A2-GB20-30

The

key causes you to exit the Configure

branch and return to the Top-Level menu. If any
changes are made to configuration options, the
SDCP allows you to save these changes to either
the Active (Saved), Customer 1, or Customer 2
configuration areas.

The

and

keys move selections across the

LCD.

The function key F2 selects the configuration
option that appears above it on the LCD.

The modem’s configuration options are arranged into

groups based upon functionality:

DTE Interface

(Table 3-4),

DTE Dialer

(Table 3-5),

Line Dialer

(Table 3-6),

Dial Line

(Table 3-7),

Leased Line

(Table 3-8),

V.42/MNP/Buffer

(Table 3-9),

Test

(Table 3-10),

Misc

(Table 3-11), and

Security

(Table 7-5

in Chapter 7).

Throughout these tables, two selections frequently

appear on the LCD: Enable and Disable. Unless
otherwise stated:

Enable selects a configuration option and makes it
available for use.

Disable makes a configuration option unavailable
for use.

Reference to particular country codes in this guide is

not an assurance that the modem has been approved for
use in that country. Consult your sales representative.

Not all configuration options are valid in all countries.

The available settings shown in this chapter are
displayed for the North America country code. See

Appendix H

.

NOTE

In some countries, the range of
allowable values of some
configuration options is restricted.
The modem will accept any
selection, but it will set the
configuration option to the closest
allowable value. The actual value
that is accepted by the modem is
displayed when the F2 key is
pressed after a selection.

DTE Interface

The DTE Interface configuration options contain

RS-232D (ITU-T V.24) and asynchronous character
format information essential for maintaining a
connection and for transmitting data between the DTE
and the modem.

Table 3-4

shows each DTE Interface configuration

option as it appears on the LCD, with the Async Dial
factory default setting (the default value if the modem is
just being installed) shown following the colon (:) on the
first line and with all available selections listed on the
second line. Following this is a description of the
configuration option, a description of the available
selections, and any equivalent AT commands.