COMSPHERE 3821Plus Modem

6-2

February 1998

3821-A2-GB20-30

NOTE

If a connection is not established
between a local COMSPHERE
modem and a remote 3821

Plus

modem, the LCD displays Remote
Mode Fail – No Circuit
. Press any
key to return to the Top Level
menu, and dial again.

If the remote modem accepts the password and the

entry is successful, the Top-Level menu of the remote
modem appears on the local modem’s LCD. An appears
in the upper right-hand corner indicating that what is
displayed on your LCD is actually the Top-Level menu of
the remote 3821Plus modem.

F1

Online : 28.8
Control ExitRem

F2

F3

The Top-Level menu of the remote 3821Plus modem is

similar to the local COMSPHERE modem with the
following exceptions:

The Modem Select branch (mdma, mdmb, mdmc)
is displayed, but cannot be used to select modems.
The modem under remote control is shown in
uppercase characters.

Change Directory is the only function available
under the Call Setup branch.

Self-Test and Local Analog Loop do not appear
under the Test branch when using the secondary
channel. When using the primary channel, the Test
branch does not appear.

In the Control branch, Make Busy is not available.

The Security Branch is not available.

Exit Remote replaces Remote on the local modem’s
LCD.

495-13082a-02

Call_Setup

Control

Test

Configure

ExitRem

Status

(Modem Status)

MDMA mdmb mdmc

To return to local modem operation, select ExitRem.

Any changes made to configuration options while using
the Remote branch are not saved until you exit the
Remote branch.

The following conditions can cause Remote Access to

fail:

The local modem is not able to communicate with
the remote modem because of a poor dial network
or leased-line connection, or the remote modem is
not a 3821Plus modem. If this is the case, the status
message No Response appears on the LCD.

If a connection is established but the remote
modem’s Access from Remote configuration option
is disabled, then the status message Access
Disabled
appears on the LCD.

If a connection is established but the wrong
password is stored, the status message Password
Invalid
appears on the LCD.