beautypg.com

Callback security, Security branch, Set access ctrl – Paradyne 3821PLUS User Manual

Page 105

background image

Security

7-3

3821-A2-GB20-30

February 1998

Callback Security

Callback Security causes the responding modem to

disconnect and call back to the phone number provided by
the user at the originating modem. The user enters the
number, when prompted by the remote modem, as a
Directory location 1–10 preceded by the # sign, or as a
complete telephone number (including the pause and wait
dial modifiers). For example:

#1

Directs the remote modem to call back to the
number stored in Directory 1

#10

Directs the remote modem to call back to the
number stored in Directory 10

9W18005551234

Directs the remote modem to dial 9, wait for
dial tone, and call back to 1-800-555-1234

If an invalid directory or telephone number is entered

but the password is correct, the modem will stay online
but will not conduct a callback sequence. The modem also
will not initiate a callback if no directory or telephone
number is specified.

Security Branch

The Security branch of the Top-Level menu allows you

to change and save parameters that are critical to the dial
access security password database. Most of the functions
within this branch are protected by the Administration
Password. Once the correct password is entered, these
security functions appear on the modem’s LCD. The
major functions that appear under the Security branch are
Set Access Control and Reset Security.

495-14847

Set_Access_Ctrl

(Admin Password?)

Reset_Security

EditPassWdTable

Set_Answer_Sec

Set_Admin_PsWd

Set_Orig_Secur

Set_CallBack_Sec

Security

Call_Setup

Control

Test

Configure

Remote

Status

(Modem Status)

MDMA mdmb mdmc

Set Access Ctrl

Set Access Control contains the Edit Password Table,

Set Answer Security, Set Originate Security, Set Callback
Security, and Set Administration Password configuration
groups.