Appendix A • Control Panel Menus
Pitney Bowes W660/W680 Operator Guide
A-25
A. Baud Rate
The Baud Rate choices are (1200), (2400), (4800), (9600) and
(19200).
B. Parity
Parity determines the integrity of data that is sent. The choices
are (ODD), (EVEN) AND (NONE).
C. Word Length
The choices are (7 DATA BITS) and (8 DATA BITS).
D. Line Termination
Typical software line termination is CR=CR;LF=LF. If your
software is not typical, the line termination can be modified.
The menu choices are (CR=CR;LF=LF), (CR=CR+LF;LF=LF),
(CR=CR;LF=CR+LF), (CR=CR+LF;LF=CR+LF).
To use the Communications option:
1. Press the ON LINE button until the display reads OFF
LINE.
2. Press the Menu button for four seconds to display the
Setup Menu.
3. Press the + or – buttons to scroll through the Setup
Menu options until the Communications option
displays on the LCD panel.
4. Press the Enter button to select the options you want.
Continue to press menu, the + and - buttons and
enter to scroll to and select the options’ next levels.
5. Communications
(continued)