Incremental fields errors, Multinational character set errors – Printronix LQH-HWTM User Manual
Page 274
274
Chapter
6
IGP/PGL Emulation Error Codes
123
EXECUTE form too long for current page setting
The form was defined in one orientation while sent to print in
another orientation. Use the debug slash (/) when creating a form
to show which element is out of bounds.
124-125
Not defined.
126
LFORMx form length parameter n error
The number of lines exceeds 66 (for 6 lpi) or 88 (for 8 lpi) lines
when using the LFORMx command.
127
Not defined.
128
FORM/LOGO name is not a legal file name
The file name exceeds the fifteen-character limitation, or an
invalid character was used in the file name. Refer to IGP
Command Standards in the “Commands” chapter.
129
Not defined.
Incremental Fields Errors
130
Not defined.
131
Incremental STEPMASK parameter error
A semicolon is missing after the STEPMASK data.
132
Incremental REPEAT/RESET parameter error
An illegal RPT or RST parameter value was found in the
incremental command. The value must range from 1 through
65,535.
133
Incremental STEPMASK/STARTDATA length error
The dynamic stepmask exceeded created field length or start
data exceeded stepmask.
134
Incremental EXECUTE command error
An illegal IRST or ICNT parameter value was found in the
Execute command. The value must range from 1 through 65,535.
135
Not defined.
136
Incremental STEPMASK/STARTDATA mismatched
The STARTDATA value must be A-Z or 0-9, when the
STEPMASK value is a value from 0-9.
Multinational Character Set Errors
150
ISET character selection parameter n error
An ISET character set selection parameter value was expected.
Error was caused possibly by an invalid numeric value or an
alpha character. See Chapter 5.
151
USET decimal input error in input parameter
The USET command was expecting a decimal parameter and
either received none or received an alpha character.
152
USET character set n parameter error
A USET character set selection parameter value between 1 and 8