Reverse print errors – Printronix LQH-HWTM User Manual
Page 273

Reverse Print Errors
273
104
Dynamic BARCODE data field BFn not previously defined
Dynamic data field designated in the Execute Form mode was
not defined in the Create Form mode.
105
Dynamic ALPHA/BARCODE field number AFn/BFn error -
must be 1-512
Dynamic alpha field number (AF
n) or bar code field number (BFn)
must range from 1 through 512.
106
Not defined.
107
Dynamic ALPHA data field AFn not previously defined
The dynamic alpha field number called for was not previously
defined in the Create Form mode.
108
Not defined.
109
Dynamic ALPHA/BARCODE field longer than previously
defined
The BARCODE data provided exceeds the maximum length for
the bar code selected.
110
SFCC decimal input error - must be 1 - 255
The hexadecimal value on the ASCII chart for the Special
Function Control Character is not valid. Refer to page 86 to select
a valid SFCC.
Reverse Print Errors
111
REVERSE format error in input parameters
Re-enter the command with proper format.
112
REVERSE starting row SR/ending row ER out of bounds
Exceeds the value specified to reverse the element.
113
REVERSE starting SC/ending column EC out of bounds
Exceeds the value specified to reverse the element.
114
Insufficient memory to store the REVERSE element
Insufficient memory space available for reversed print
requirements.
115
PDF417 bar code sizing parameter illegal or too small for
data
116
PDF417 security level has illegal value or format
117
Unusable or illegal raster data.
118
Unsupported raster image type.
119
Unsupported raster compression type.
120-121
Not defined.
122
EXECUTE form too wide for current page setting
The form was defined in one orientation while sent to print in
another orientation. Use the debug slash (/) when creating a form
to show which element is out of bounds (see page 314).