Message Description
Action
Select License
The correct protocol has not been selected
from the license set.
Using the administrative menus, select one
license from the set to allow the phone to
download the appropriate software.
Server Busy
Handset is attempting to download from a
TFTP server that is busy downloading other
devices and refusing additional downloads.
None, the handset will automatically retry
the download every few seconds.
Skt Open Fail
Socket open fail. Occurs when the Handset
tries to connect to the PBX but there is no
response. If resiliency is active, the handset
will keep trying.
If the PBX is inoperative and resiliency is
not active or the handset cannot locate a
backup PBX, turn off the handset and
repair the primary PBX. Note that it may be
advisable to reconfigure the backup PBX to
be the primary PBX if the repair is more
time-consum-ing than the reconfiguration.
Storing Config
Handset is storing changes to handset
configuration.
None. Informational only. The handset may
display this briefly following a
configuration change or software
download.
SVP Service Rej.
The NetLink SVP Server has rejected a
request from the handset
The handset will restart and attempt to re-
register with the SVP Server, which should
fix the problem. Report to your
administrator if it keeps happening.
System Busy
yyy.yyy.yyy.yyy
y…y = SVP Server IP Address
SVP Server has reached call capacity.
All call paths are in use, try the call again
in a few minutes.
System Locked
(with Busy Tone)
NetLink SVP Server is locked
Try call again later, system has been
locked for maintenance
System Gateway is locked
Try the call again, system has been locked
for maintenance
TCP Rcv Timeout
If the PBX has failed, this message may
display briefly as the handset tries to connect
to the backup PBX in a resilient setting. This
message may be replaced by the SKT Open
Fail message if the handset is unsuccessful
at connecting with the backup PBX or if
resiliency is not programmed.
Wait for the handset to cycle through
attempts to connect to the backup PBX.
See SKT Open Fail above.