beautypg.com

Miscellaneous control, Data log control, Media control – Panasonic WJ-HD100 User Manual

Page 48

background image

49

Miscellaneous Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Playback Speed

LTM:n

LTM

n=0-F
n=0

11 ............. Fastest

n=1

10

n=2

9

n=3

8

n=4

7

n=5

6

n=6

5

n=7

4

n=8

3

n=9

2

n=A

1

n=B

1/2

n=C

1/4

n=D

1/8

n=E

1/16

n=F

1/32 ...........Slowest

Data Copy Cancel

ZDC

ZDC

Data Copy

ZDP:nn

ZDP

nn=00 Copy until the card is full
nn=01 Copy 1 field
nn=08 Copy 8 fields
nn=16 Copy 16 fields
nn=32 Copy 32 fields
nn=48 Copy 48 fields

Time&Date Search

ZTS:yyyymmddhhnnss

ZTS

yyyy=Year
mm=Month
dd=Day
hh=Hour (24-hour system)
nn=Minute
ss=Second

Communication Check RCK

RCK

Data Log Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Log Total Size Inquiry

ILB:k

ILB:k:bbb

k=0

Alarm log

bbb=001 to 099 (in decimal)

Log Erase

ILC:k

ILC:k

k=0

Alarm log

Log Recorded

ILQ:k

ILQ:k:bbb:(:E)

k=0

Alarm log

Size Inquiry

bbb=001 to 099 (in decimal)
E=Overwrite

Log Readout

ILR:k:sss:mmm

ILR:k:s1

k=0 Alarm log

s2

sss=001-099 Start Address

F

mmm=001-099 Decimal # of log
=yymmddhhnnss
sn=0-9 and F

Cyclic number

(F is put at data end)

Media Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Disk End Notice Setup

MDE:n

MDE

n=0

End is not notified

n=1

End is notified

Disk End Notice

HDE