Mode switch setting, Unit address & initialize, Termination – Panasonic WJ-HD100 User Manual
Page 14: Alarm output polarity
![background image](/manuals/172245/14/background.png)
ALARM RECOVER OUT
14
MODE
ON
Termination
Unit Address/Initializing
Alarm Out Polarity
1 2 3 4
5 6
■
Mode Switch Setting
The 6-bit DIP switch on the rear panel is used as follows.
#1 through #4:
For setting the unit address or initializ-
ing the setup data
#5:
Termination for communication lines
#6:
For setting the polarity of the alarm output signal
●
Unit Address & Initialize
The unit address can be set either on the setup menu
or by setting this DIP switch.
MODE
ON
1 2 3 4
5 6
MODE
ON
1 2 3 4
5 6
MODE
ON
1 2 3 4
5 6
MODE
ON
1 2 3 4
5 6
MODE
ON
1 2 3 4
5 6
Unit address is specified in
the setup window.
Unit address 1
Unit address 2
Unit address 3
All disk contents and setup
data are initialized.
Note: Do not use switch combinations other than shown above.
●
Termination
Set DIP switch #5 to ON or OFF position depending on the
type of connection and the unit's position within the daisy
chain.
Daisy Chain Connection:
Set the termination to ON for the
units at both ends of the RS-485 chain (PS
•
Data), and to
OFF for units in the middle.
Homerun Connection:
For a one-to-one connection, set
the termination to ON.
ON
Termination Switch
MODE
1 2 3 4
5 6
System Component
Termination ON
Termination OFF
Termination
OFF
Termination
OFF
Termination
ON
System
Controlle
r WU-CU
360
360
For PS.D
.LINK
8
9
7
0
4
5
6
2
3
1
System
Controlle
r WU-CU
360
360
For PS
.D.LIN
K
8
9
7
0
4
5
6
2
3
1
System
Controlle
r WU-CU
360
360
For P
S.D.LINK
8
9
7
0
4
5
6
2
3
1
●
Alarm Output Polarity
The DIP switch #6 specifies the polarity of ALARM OUT and
ALARM RECOVER output signals. Select [active-low] or
[active-high] depending on the type of the connected
device. See the manual included in the connected device
for acceptable signal polarity. The default setting is ON
[active-high].
MODE
ON
Polarity switch
1 2 3 4
5 6
Switch #6 vs Polarity (when active)
ALARM OUT
ON (active-high)
OFF (active-low)
Open-collector low
Open-collector low
+12 V DC
+5 V DC