Ending an Active Test

A test initiated by the user can be ended by the user. Tests can also be
terminated automatically by enabling the Test Timeout option from the System
Options Menu.

H

A Test Timeout option is available to automatically terminate a Loopback or
Pattern test (as opposed to manually terminating a test) after it has been
running a specified period of time. The default is 10 minutes.
Refer to Table A-3,

System Options

.

H

On each test screen is a Command column. To stop the test, press Enter
when the cursor is on the Stop command.

H

Use the Abort Tests selection from the Test menu to stop all tests running on
all interfaces, with the exception of network-initiated loopbacks.

Command

Complete

appears when all tests on all interfaces have been terminated.

An aborted test may continue to run for a few seconds as the abort command
is sent to the remote end and processed.

Telco-Initiated Tests

The Hotwire 7984 Standalone Termination Unit supports Telco-initiated tests as
shown in the following table.

Activation and
Deactivation

Line Loopback

Payload Loopback

Remote Line
Loopback

In-Band Signal

Supported

Not Applicable

Not Supported

Bit-Oriented

Supported

Supported

Supported

Message-Oriented

Not Applicable

Not Supported

Not Applicable

Telco-Initiated Line Loopback

The Hotwire 7984 Standalone Termination Unit supports line loopback as
specified in AT&T TR 54016, AT&T TR 62411, and ANSI T1.403. A Telco-initiated
line loopback loops the received signal on the DSX-1 interface back to the DSX-1
interface without modification. Framing, CRC, and FDL bits are returned
unaltered, and no BPVs or other line coding errors are removed.

CAP

DSL
Port

DSX-1
Port

CAP

T1

LIU

Framer

Framer

Transceiver

99-16252

All Ones

Telco