beautypg.com

Health and status, Able 4-1, Health and status messages – Paradyne HOTWIREt 7984 User Manual

Page 45

background image

Monitoring the Unit

4-3

7984-A2-GB20-10

February 1999

Health and Status

The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.

Table 4-1.

Health and Status Messages (1 of 2)

Message

What Message Indicates

What To Do

System Operational

There are no problems
detected.

LOS at Net, Pt 1

An LOS (Loss Of Signal)
condition has been
detected on the network
interface. No signal is
being received on Port 1,
possibly due to a local
network problem.

1. Verify that the network cable is

securely attached at both ends.

2. Verify proper NTU and LTU

configuration

3. Contact network provider.

OOF at Net, Pt 1

An OOF (Out Of Frame)
condition has been
detected at the network
interface.

Contact network provider.

LOS at DSX-1, Pt 1

An LOS (Loss Of Signal)
condition has been
detected on the DSX-1
interface.

1. Verify proper framing.

2. Contact network provider.

NTU/LTU Mis match,
Pt 1

The NTU is not configured
the same as the LTU.

Configure units to match.

LOF at DSX-1, Pt 1

An LOF (Loss Of Frame)
condition has been
detected on the DSX-1
interface.

1. Verify that the network cable is

securely attached at both ends.

2. Contact network provider.

AIS at DSX-1, Pt 1

An Alarm Indication Signal
(AIS) is being received by
the DSX-1 interface.

1. Verify that the units line framing

and line coding are compatible.

2. Contact network provider.

EER at Net, Pt 1

An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.

1. Ignore condition if 511 test active.

2. Contact network provider.

EER at DSX-1, Pt 1

An EER (Excessive Error
Rate) condition has been
detected on the DSX-1
interface.

1. Verify the attached equipment

coding is compatible.

2. Contact network provider.

Yellow alarm at
DSX-1, Pt 1

A Yellow Alarm Indication
signal is being received by
the DSX-1 interface.

1. Verify that the units line framing

and line coding are compatible.

2. Contact network provider.