Hydronic piping – Lochinvar Outdoor Knight Boiler 151-286 User Manual

Page 19

background image

19

3

Hydronic piping

(continued)

Please note that these illustrations are meant to show system piping concept only, the installer is responsible
for all equipment and detailing required by local codes.

Indoor tank shown for illustration purposes.

NOTICE

BOILER

INDIRECT

DHW TANK

DOMESTIC

HOT WATER

CIRCULATOR

ANTI-SCALD
MIXING VALVE

COLD
WATER
IN

TEMPERATURE /

PRESSURE

GAUGE

AIR SEPARATOR

BALL VALVE

(TYPICAL)

UNION

(TYPICAL)

DRAIN POINT

(TYPICAL)

MAKE

UP

WATER

HOT WATER

OUT

BOILER
CIRCULATOR

BACKFLOW

PREVENTER

PRESSURE

GAUGE

EXPANSION

TANK

MIXING VALVES

(TYPICAL)

FLOW CHECK
VALVE

SYSTEM

SUPPLY
SENSOR

DRAIN

Y-STRAINER
(RECOMMENDED)

MAY SUBSTITUTE
LOW LOSS HEADER

TEMPERATURE

LOOP #1

TEMPERATURE

LOOP #2

TEMPERATURE

LOOP #3

NOT TO EXCEED 4 PIPE DIA
OR MAX. OF 12" APART

PRESSURE
REDUCING VALVE

SHIELDED CABLE TO

BOILER CONTROL

WIRES TO
LOOP SENSORS

MULTI-TEMP
LOOP CONTROL

120VAC TO PUMPS

24V SIGNALTO

MIXING VALVES

IMG00372

Figure 3-6 Single Boiler - Multiple Temperatures

CAUTION

Mixing valves are required for the protection of low temperature loops.

Outdoor Knight Boiler Installation & Operation Manual