Hydronic piping – Lochinvar Outdoor Knight Boiler 151-286 User Manual

Page 17

background image

17

3

Hydronic piping

(continued)

BOILER

INDIRECT

DHW TANK

DOMESTIC

HOT WATER

CIRCULATOR

BACKFLOW

PREVENTER

PRESSURE

REDUCING VALVE

PRESSURE

GAUGE

ANTI-SCALD

MIXING VALVE

COLD

WATER

IN

TEMPERATURE /

PRESSURE

GAUGE

AIR SEPARATOR

EXPANSION

TANK

ZONE #1

ZONE #2 ZONE #3 ZONE #4

BALL VALVE

(TYPICAL)

UNION

(TYPICAL)

DRAIN

DRAIN POINT

(TYPICAL)

MAKE UP WATER

HOT

WATER

OUT

ZONE CIRCULATORS

(TYPICAL)

FLOW CHECK

VALVE

(TYPICAL)

BOILER
CIRCULATOR

SYSTEM SUPPLY

SENSOR

(WHEN USED)

Y-STRAINER
(RECOMMENDED)

MAY SUBSTITUTE LOW LOSS HEADER

IMG00370

Figure 3-4 Single Boiler - Single Temperature Zoned with Circulators

Please note that these illustrations are meant to show system piping concept only, the installer is responsible
for all equipment and detailing required by local codes.

Indoor tank shown for illustration purposes.

NOTICE

Outdoor Knight Boiler Installation & Operation Manual