beautypg.com

Post error codes, Post, Error – Lenovo THINKCENTRE 8177 User Manual

Page 91: Codes

background image

POST

error

codes

Each

time

you

power-on

the

system,

it

performs

a

series

of

tests

that

check

the

operation

of

the

system

and

some

options.

This

series

of

tests

is

called

the

Power-On

Self-Test,

or

POST.

POST

does

the

following

operations.

v

Checks

some

basic

system-board

operations

v

Checks

the

memory

operation

v

Starts

the

video

operation

v

Verifies

that

the

diskette

drive

is

working

v

Verifies

that

the

hard

disk

drive

is

working

If

the

POST

finishes

without

detecting

any

problems,

a

single

beep

sounds

and

the

first

screen

of

the

operating

system

or

application

program

appears.

If

the

POST

detects

a

problem,

an

error

message

appears

on

the

screen.

A

single

problem

can

cause

several

error

messages

to

appear.

When

you

correct

the

cause

of

the

first

error

message,

the

other

error

messages

probably

will

not

appear

on

the

screen

the

next

time

you

turn

on

the

system.

In

the

following

index,

X

can

represent

any

number.

POST

Error

Code

FRU/Action

162

Configuration

error

Select

the

default

settings

in

BIOS.

See

Chapter

6,

“Using

the

Setup

Utility,”

on

page

55.

164

Memory

Size

Error

1.

Run

the

Extended

Memory

Diagnostic

tests

2.

Replace

memory

modules

166

Boot

Block

Check

Sum

Error

1.

Perform

a

flash

update

to

update

the

BIOS

level

2.

System

board

167

No

Processor

BIOS

update

found

1.

Run

Setup.

Check

Stepping

level

for

the

BIOS

level

needed,

then

perform

the

flash

update.

2.

Replace

the

microprocessor

175

Primary

Copy

of

Secure

Data

is

damaged

1.

Run

Setup

and

select

default

settings

2.

System

board

176

The

System

has

been

tampered

with

1.

Covers

were

removed

from

the

computer

179

Boot

Integrity

Services

Segment

Error

1.

Perform

a

flash

update

to

update

the

BIOS

level

2.

System

board

184

Asset

Control

Antenna

not

detected

1.

Make

sure

Asset

Care

and

Asset

ID

are

enabled

in

Configuration/Setup

2.

RFID

Antenna

3.

Replace

system

board

186

Security

Hardware

Control

Logic

Error

If

problem

persists,

replace

the

system

board

190

System

Security:

Invalid

Remote

Change

Requested

If

problem

persists,

replace

the

system

board

Chapter

7.

Symptom-to-FRU

Index

85