beautypg.com

Lenovo THINKCENTRE 8177 User Manual

Page 84

background image

Diagnostic

Error

Code

FRU/Action

170-0XX-XXX

Voltage

Sensor(s)

failure

1.

Flash

system

2.

System

board

170-195-XXX

Voltage

Sensor(s)

Test

aborted

by

user

Information

only

Re-start

the

test,

if

necessary

170-196-XXX

Voltage

Sensor(s)

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

170-197-XXX

Voltage

Sensor(s)

test

warning

1.

Make

sure

the

component

that

is

called

out

is

connected

and/or

enabled.

See

Chapter

6,

“Using

the

Setup

Utility,”

on

page

55

2.

Re-run

test

3.

Replace

the

component

that

is

called

out

in

warning

statement

4.

Replace

the

component

under

test

170-198-XXX

Voltage

Sensor(s)

test

aborted

1.

If

a

component

is

called

out,

make

sure

it

is

connected

and/or

enabled.

See

Chapter

6,

“Using

the

Setup

Utility,”

on

page

55

2.

Flash

the

system

and

re-test.

See

“Flash

update

procedures”

on

page

214

3.

Go

to

“Undetermined

problems”

on

page

90

170-199-XXX

Voltage

Sensor(s)

test

failed,

cause

unknown

1.

See

“Undetermined

problems”

on

page

90

2.

Flash

the

system

and

re-test.

See

“Flash

update

procedures”

on

page

214

3.

Replace

component

under

function

test

170-250-XXX

170-251-XXX

Voltage

Sensor(s)

Voltage

limit

error

1.

Power

supply

2.

System

board

170-254-XXX

Voltage

Sensor(s)

Voltage

Regulator

Module

error

1.

Voltage

Regulator

Module

(VRM)

2.

Microprocessor

3.

System

board

175-000-XXX

Thermal

Sensor(s)

Test

Passed

No

action

175-0XX-XXX

Thermal

Sensor(s)

failure

1.

Flash

system

2.

System

board

175-195-XXX

Thermal

Sensor(s)

Test

aborted

by

user

Information

only

Re-start

the

test,

if

necessary

175-196-XXX

Thermal

Sensor(s)

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

78

Hardware

Maintenance