Function
Code
Minimum Level Required
Notes
N
R
U
C
A
PRTSTOP
094
X
RMTPTDEF
209
X
X
X
READ (or higher) lets users view
the remote session definitions.
UPDT (or higher) lets users change
remote session definitions and the
SLU session ID prefix. ALTR lets
users add and delete remote
session definitions.
RMTPTSEL
207
X
SECFUNCS
243
X
SECFUNDF
245
X
SECURITY
240
X
X
READ (or higher) lets users access
the Security Definitions Menu.
UPDT (or higher) is required to
change the type of logon and
function security used.
SHIFTDEF
177
X
X
READ (or higher) lets users view
the Shift Definition Facility. UPDT
(or higher) is required to update
shift definitions.
SHUTDOWN
003
X
SIGNON
001
X
STORTCBS
221
X
STORTIOT
220
X
STRGALTR
211
X
Works with the STRGNPRV and
STRGPRV functions. To alter
private storage, READ access must
be specified for STRGALTR and
UPDT must be specified for
STRGPRV. To alter nonprivate
storage, READ access must be
specified for STRGALTR and UPDT
must be specified for both
STRGPRV and STRGNPRV.
STRGDSPY
137
X
Works with the STRGNPRV and
STRGPRV functions. To display
private storage, READ access must
be specified for both STRGDSPY
and STRGPRV. To display
nonprivate storage, READ access
must be specified for both
STRGDSPY and STRGNPRV.
STRGNPRV
115
X
X
Works with the STRGDSPY,
STRGALTR, and STRGPRV
functions. To alter nonprivate
storage, you must be authorized to
alter private and nonprivate
storage. See the above notes for
the STRGDSPY and STRGALTR
functions for the authorization
required to display and alter
nonprivate storage.
Function Access Level Table
Chapter 2: Security Definitions
2-54