Table 7.1 absolute maximum stress ratings, Table 7.2 operating conditions, Absolute maximum stress ratings – LSI 53C810A User Manual
Page 184: Operating conditions, Table 7.1
7-2
Electrical Characteristics
Table 7.1
Absolute Maximum Stress Ratings
Symbol
Parameter
Min
Max
Unit
Test Conditions
T
STG
Storage temperature
−
55
150
°
C
–
V
DD
Supply voltage
−
0.5
7.0
V
–
V
IN
Input voltage
V
SS
−
0.5
V
DD
+0.5
V
–
I
LP
1
1.
−
2 V < V
PIN
< 8 V.
Latch-up current
±
150
–
mA
–
ESD
2
2. SCSI pins only.
Note: Stresses beyond those listed above may cause permanent damage to the device. These are
stress ratings only; functional operation of the device at these or any other conditions beyond
those indicated in the
section of the manual is not implied.
Electrostatic discharge
–
2 K
V
MIL-STD 883C,
Method 3015.7
Table 7.2
Operating Conditions
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
DD
Supply voltage
4.75
5.25
V
–
I
DD
1
1. Average operating supply current is 50 mA.
Note: Conditions that exceed the operating limits may cause the device to function incorrectly.
Supply current (dynamic)
Supply current (static)
–
–
130
1
mA
mA
–
–
T
A
Operating free air
0
70
°
C
–
θ
JA
Thermal resistance
(junction to ambient air)
–
67
°
C/W
–