beautypg.com

Table 7.1 absolute maximum stress ratings, Table 7.2 operating conditions, Absolute maximum stress ratings – LSI 53C810A User Manual

Page 184: Operating conditions, Table 7.1

background image

7-2

Electrical Characteristics

Table 7.1

Absolute Maximum Stress Ratings

Symbol

Parameter

Min

Max

Unit

Test Conditions

T

STG

Storage temperature

55

150

°

C

V

DD

Supply voltage

0.5

7.0

V

V

IN

Input voltage

V

SS

0.5

V

DD

+0.5

V

I

LP

1

1.

2 V < V

PIN

< 8 V.

Latch-up current

±

150

mA

ESD

2

2. SCSI pins only.
Note: Stresses beyond those listed above may cause permanent damage to the device. These are

stress ratings only; functional operation of the device at these or any other conditions beyond
those indicated in the

Operating Conditions

section of the manual is not implied.

Electrostatic discharge

2 K

V

MIL-STD 883C,

Method 3015.7

Table 7.2

Operating Conditions

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

DD

Supply voltage

4.75

5.25

V

I

DD

1

1. Average operating supply current is 50 mA.
Note: Conditions that exceed the operating limits may cause the device to function incorrectly.

Supply current (dynamic)
Supply current (static)


130

1

mA
mA


T

A

Operating free air

0

70

°

C

θ

JA

Thermal resistance
(junction to ambient air)

67

°

C/W