LSI 53C810A User Manual
Page 101
5-27
3. Read the
register.
4. If the SCSI Interrupt Pending bit is set, then read the
SCSI Interrupt Status Zero (SIST0)
or
register to determine the cause of
the SCSI Interrupt and go back to Step 2.
5. If the SCSI Interrupt Pending bit is clear, and the DMA
Interrupt Pending bit is set, then write 0x00 value to
this register.
6. Read the
register to verify the
aborted interrupt and to see if any other interrupting
conditions have occurred.
SRST
Software Reset
6
Setting this bit resets the LSI53C810A. All operating
registers are cleared to their respective default values
and all SCSI signals are deasserted. Setting this bit does
not assert the SCSI RST/ signal. This reset does not
clear the LSI53C700 family compatibility bit or any of the
PCI configuration registers. This bit is not self-clearing; it
must be cleared to clear the reset condition (a hardware
reset also clears this bit).
SIGP
Signal Process
5
SIGP is a R/W bit that is writable at any time, and polled
and reset using
. The SIGP bit
is used in various ways to pass a flag to or from a running
SCRIPTS instruction.
The only SCRIPTS instruction directly affected by the
SIGP bit is Wait for Selection/Reselection. Setting this bit
causes that instruction to jump to the alternate address
immediately. The instructions at the alternate jump
address should check the status of SIGP to determine
the cause of the jump. The SIGP bit may be used at any
time and is not restricted to the wait for selection/
reselection condition.
SEM
Semaphore
4
The SCRIPTS processor may set this bit using a
SCRIPTS register write instruction. An external processor
may also set it while the LSI53C810A is executing a
SCRIPTS operation. This bit enables the LSI53C810A to
notify an external processor of a predefined condition
while SCRIPTS are running. The external processor may