To Reset Calibration:

1. Press

MENU

|

MENU

, select

NMEA

2000

and press

ENT

.

2. Highlight

F

UEL

M

ANAGEMENT

and press

ENT

.

3. Highlight

E

NGINE

S

ELECT

and press

ENT

. The Engine Select menu will

appear with up to four options: All Engines, Port, Center and Star-

board. Selecting All Engines will reset calibration for all engines back

to factory defaults.
4. Select All Engines or the engine connected to the desired device and

press

ENT

.

5. Highlight

R

ESET

C

ALIBRATION

and press

ENT

. The following message

will appear: Are you sure you wish to Reset Calibration?
6. Highlight

Y

ES

and press

ENT

. Press

EXIT

repeatedly to get back to the

main display.
EP-15 Fluid Level Calibration
The default calibration for the EP-15 Fluid Level is just as accurate as

standard fluid level gauges. If, however, the tank has an irregular

shape or greater accuracy is needed, calibration is recommended. There

are three calibration options: 2-Point, 3-Point and 5-Point.

2-Point Calibration

A 2-point calibration is best suited for rectangular or square-shaped

tanks, where the capacity of the top half of the tank matches the capac-

ity in the lower half of the tank. In a two-point calibration, you will set

two points, one each for empty and full levels. You can begin calibra-

tion at either of the two points, but we recommend starting with an

empty tank. You will fill the tank to complete calibration.
1. Press

MENU| MENU

, use

↓ ↑ to select

NMEA

2000

and press

ENT

.

2. Highlight

B

US

S

ETUP

and press

ENT

, which will open the Bus Configu-

ration menu. A list of network devices will be at the top of the page.
3. Select the EP-15 Fluid Level and press

ENT

.

4. Press

↓ to select

C

ALIBRATE

and press

ENT

. The Device Calibration

menu will appear. Instructions on Calibration will be listed at the top

of the menu.
5. Highlight

N

UM

P

TS

,

press

ENT

and select

2.

Press

ENT

.

6.

Select F

LUID

L

EVEL

, press ENT, then select E

MPTY

L

EVEL

and

press

ENT.

7. Make sure the fuel tank is empty, highlight

C

ALIBRATE

and press

ENT

.

The following message will appear: Empty Level Calibration Com-
pleted.

Press ENT.

8.

Fill up your tank, highlight

F

LUID

L

EVEL

and press

ENT.

9.

Select

F

ULL

L

EVEL

and press

ENT.

Highlight

C

ALIBRATE

and press

ENT.