Installation, Technical specifications - idealarc cv-300 – Lincoln Electric IDEALARC CV-300 User Manual
Page 8
Duty Cycle
Amps
Volts at Rated Amps
CV-300
100%
300A
32
60%
400A
36
Current Range
Maximum Open Circuit Voltage
Auxiliary Power
50A - 400A
55V
115 VAC, 5AMPS
42 VDC, 10AMPS
Input Voltage/
Fuse (Superlag)
Type 75
0
C wire in
Type 75
0
C Copper
Frequency
or Breaker Size
Copper conduit AWG
Ground Wire in Conduit
(IEC Sizes)
208/60
100
4 (25mm
2
)
6 (16mm
2
)
230/60
100
4 (25mm
2
)
8 (10mm
2
)
460/60
50
10 (6mm
2
)
10 (6mm
2
)
575/60
40
10 (6mm
2
)
10 (6mm
2
)
200/50/60
100
4 (25mm
2
)
6 (16mm
2
)
220/50/60
100
4 (25mm
2
)
8 (10mm
2
)
230/50/60
100
4 (25mm
2
)
8 (10mm
2
)
380/50/60
70
8 (10mm
2
)
8 (10mm
2
)
400/50/60
50
8 (10mm
2
)
10 (6mm
2
)
415/50/60
50
8 (10mm
2
)
10 (6mm
2
)
440/50/60
50
10 (6mm
2
)
10 (6mm
2
)
500/50/60
50
10 (6mm
2
)
10 (6mm
2
)
HEIGHT
WIDTH
DEPTH
LIFT HOOK
WEIGHT
ADD
21.5”
19.5”
27.0”
3.12”
300 lbs.
(546mm)
(495mm)
(686mm)
(80mm)
(136 Kg.)
Standard Voltages
Input Current at Rated Output
208/230/460/3/60
66/60/30 Amps
230/460/575/3/60
60/30/24 Amps
A-1
INSTALLATION
IDEALARC CV-300
A-1
TECHNICAL SPECIFICATIONS - IDEALARC CV-300
INPUT - THREE PHASE/ 50-60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE & FUSE SIZE
PHYSICAL DIMENSIONS