Operation, Safety instructions, General description – Lincoln Electric IDEALARC CV-300 User Manual
Page 18: Warning, Caution

B-1
OPERATION
B-1
Read and understand this entire section before
operating your Idealarc CV-300.
SAFETY INSTRUCTIONS
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as output terminals or internal wiring.
• Insulate yourself from the work and
ground.
• Always wear dry insulating gloves.
____________________________________
____________________________________
____________________________________
____________________________________
Only qualified personnel should operate this equip-
ment. Observe all safety information throughout this
manual.
When using a CV-300 power source with wire feed-
ers, there will be a small spark if the electrode con-
tacts the work or ground within several seconds
after releasing the trigger.
When use with some wire feeders with the electri-
cal trigger interlock in the ON position, the arc
might restart if the electrode touches the work or
ground during these several seconds.
____________________________________
GENERAL DESCRIPTION
Product Description
The IDEALARC CV-300 is a constant voltage DC
power source designed for the GMAW process with
limited FCAW capability. It features an industrial rating
of 300 amps, 32 volts, at 100% duty cycle. It complies
with the requirements for a NEMA Class I (100) power
source. It is available from the factory in one model
only, with no options other than input voltage or fre-
quency.
No options are available other than input voltage.
The IDEALARC CV-300 includes the following fea-
tures:
•
Two inductance positions: operator can
choose the optimum output characteristics.
•
Solid State Output Contactor: no noise, no
moving parts to wear.
•
Digital Voltmeter/Ammeter is standard.
•
42 VAC, 10 amp auxiliary power available for
the wire feeder.
•
Circuit breaker protected.
•
115 VAC, 5 amp auxiliary power available for
the wire feeder; circuit breaker protected.
IDEALARC CV-300
WARNING
FUMES AND GASES
can be dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to
remove fumes from breathing
zone.
ARC RAYS
can burn.
• Wear eye, ear and body
protection.
WELDING, CUTTING and
GOUGING SPARKS
can cause fire or explosion
• Keep flammable material away.
• Do not weld, cut or gouge on
containers that have held com-
bustibles.
CAUTION