Precautions for Installation of the Bushings
Make sure that the slits in the bushing are properly

aligned with the rib of the Fusing Unit.

4136D040AA

Upper Fusing
Roller
section

5. Remove one screw and the Thermistor.

NOTE
When reinstalling the Thermistor, route the har-

ness as shown in the illustration.

4980D068AB