DS6707 Digital Imager Scanner Product Reference Guide
Buffer Code 39
71h
Disable
Code 93
Code 93
09h
Disable
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
Code 11
Code 11
0Ah
Disable
Set Lengths for Code 11
1Ch 1Dh
4 to 55
Code 11 Check Digit Verification
34h
Disable
Transmit Code 11 Check Digit(s)
2Fh
Disable
Interleaved 2 of 5 (ITF)
Interleaved 2 of 5 (ITF)
06h
Enable
Set Lengths for I 2 of 5
16h 17h
14
I 2 of 5 Check Digit Verification
31h
Disable
Transmit I 2 of 5 Check Digit
2Ch
Disable
Convert I 2 of 5 to EAN 13
52h
Disable
Discrete 2 of 5 (DTF)
Discrete 2 of 5
05h
Disable
Set Length(s) for D 2 of 5
14h 15h
12
Codabar (NW - 7)
Codabar
07h
Disable
Set Lengths for Codabar
18h 19h
5 to 55
CLSI Editing
36h
Disable
NOTIS Editing
37h
Disable
MSI
MSI
0Bh
Disable
Set Length(s) for MSI
1Eh 1Fh
1 to 55
MSI Check Digits
32h
One
Transmit MSI Check Digit
2Eh
Disable
Table A-1
Standard Default Parameters Table (Continued)
Parameter
Parameter
Number
Default
Page
Number
1