Unpacking and Installing the Panel PC 670/870

Release 11/02

1–6

SIMATIC Panel PC 670/870 Start-Up Instructions

Select installation cut-out

Step 6

Apples to the computer in a decentralized design:

No installation cut-out is required for the computer. Skip this working step.

Applies to both centralized and decentralized designs:

Select an appropriate installation area taking the installation notes and selected
installation angle into account.

Note

Ensure sufficient air volume for heat transportation within the switching
cabinet/panel. Further information on this is available in the Panel PC 670/870
Operating Unit Equipment Manual, Chapter 2.4.
Also ensure sufficient free space to pull out the Panel PC 670/870 from the
installation cut-out.

When selecting the installation cut-out, ensure that the switching cabinet/panel
contains reinforcement bars to stabilize the cut-out. If necessary, install such
reinforcement bars.

Figure 1–6 below contains:

the dimensioning of the holes required for the retaining screws and

the dimensioning of the pressure points of the screws regarding the clamping
saddles.