Sony SRP-X700P User Manual
Page 8
8
1-3 (6) Connection between SRP-X700P and VPL-PX40
OUTPUT
R/R-Y
VIDEO
S VIDEO
CONTROL S
CONTROL S
IN
OUT
RS-232C
OUTPUT
G/Y
B/B-Y
SYNC/HD
VD
1
2
3
4
PROJECTOR CONTROL
D-sub 9P male – D-sub 9P male (RS-232C)
5BNC-5BNC (RGB and Component)
BNC – Phono (Composite)
Mini DIN – Mini DIN (S VIDEO)
SRP-X700P OUTPUT
VPL-PX40 INPUT
•
S VIDEO is not applied for this application, it’s not necessary to connect the S VIDEO. This
system configuration (on page-3) uses composite connection.
•
In case the component connection is not applied in the setup box on REMOTE SCREEN of
Manager GUI (as example of page-3, 6 and 7), the component input of the PX40 is not selected
because of no selection command from X700P through RS -232C, although 5-BNC’s are
connected.
1-3 (7)
70V Ceiling Speaker
Connection with SRP-X700P
SPEAKER OUTPUT Box of OUTPUT SCREEN, 70V LINE is selected.
When 70V line is selected this sets SRP-X700P amplifier to mono, setup box for CH2 closes.
OUTPUT3 is selected in the Box on
OUTPUT SCREEN on Manger GUI.
Attenuation for the amplifier is set to
provide adequate sound level within the
listening area.
SRP-X700P SPEAKER OUTPUT
SPEAKERS
IMPEDANCE USE
4-16
70V LINE
CH-1
CH-2
IMPEDANCE USE
4-16
IMPEDANCE USE 32
-10k
Connection of 816 ohms (6W), 700
ohms (7W) or 613 ohms (8W) for the
ceiling speakers (Connection is in
parallel.)