beautypg.com

Sony SRP-X700P User Manual

Page 8

background image

8

1-3 (6) Connection between SRP-X700P and VPL-PX40

OUTPUT

R/R-Y

VIDEO

S VIDEO

CONTROL S

CONTROL S

IN

OUT

RS-232C

OUTPUT

G/Y

B/B-Y

SYNC/HD

VD

1

2

3

4

PROJECTOR CONTROL

D-sub 9P male – D-sub 9P male (RS-232C)

5BNC-5BNC (RGB and Component)

BNC – Phono (Composite)

Mini DIN – Mini DIN (S VIDEO)

SRP-X700P OUTPUT

VPL-PX40 INPUT

S VIDEO is not applied for this application, it’s not necessary to connect the S VIDEO. This
system configuration (on page-3) uses composite connection.

In case the component connection is not applied in the setup box on REMOTE SCREEN of
Manager GUI (as example of page-3, 6 and 7), the component input of the PX40 is not selected
because of no selection command from X700P through RS -232C, although 5-BNC’s are
connected.

1-3 (7)

70V Ceiling Speaker

Connection with SRP-X700P

SPEAKER OUTPUT Box of OUTPUT SCREEN, 70V LINE is selected.

When 70V line is selected this sets SRP-X700P amplifier to mono, setup box for CH2 closes.

OUTPUT3 is selected in the Box on
OUTPUT SCREEN on Manger GUI.

Attenuation for the amplifier is set to
provide adequate sound level within the
listening area.

SRP-X700P SPEAKER OUTPUT

SPEAKERS

IMPEDANCE USE

4-16

70V LINE

CH-1

CH-2

IMPEDANCE USE

4-16

IMPEDANCE USE 32

-10k

Connection of 816 ohms (6W), 700
ohms (7W) or 613 ohms (8W) for the
ceiling speakers (Connection is in
parallel.)