beautypg.com

B.1.3 absolute maximum ratings, B.1.4 normal operating ranges, B.2 reliability – Sun Microsystems SUN NETRA CP3000 User Manual

Page 62: B.1.3, Absolute maximum ratings, B.1.4, Normal operating ranges, Reliability

background image

B-4

Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

B.1.3

Absolute Maximum Ratings

The following values are stress ratings only. Do not operate at these maximums. See

Section B.1.4, “Normal Operating Ranges” on page B-4

for normal operating

conditions.

B.1.4

Normal Operating Ranges

*The MTBF will be significantly reduced if operated above 30˚C for more than 96 consecutive hours.

B.2

Reliability

Reliability prediction was done using Telcordia document SR-332, Issue 1. The
prediction assumed 25˚ Celsius operating temperature with 100 percent duty cycle,
in a ground-benign, controlled environment.

MTBF: 630,000 hours

One year limited warranty

Payload voltage, +12V

0 VDC to +13.2 VDC

Management voltage, +3.3V

3.135 VDC to +3.465
VDC

Storage temperature

–40 to +70˚ Celsius

Noncondensing relative humidity

5% to 95% at 29˚ Celsius

Description

Range

Nominal operating voltage

+10.8 to +13.2 VDC payload power
3.135 VDC to +3.465 VDC management
power

Operating temperatures*:
• 60m below sea level up to 1800m above sea

level

• from 1800m up to 4000m above sea level

–5˚ to +55˚C

–5˚ to +40˚C

Operating humidity

Less than 85% at 29˚C

Idle power consumption (without links)

9W

Maximum power consumption

12W