Basic operations – Simrad EQ60 User Manual
Page 53
![background image](/manuals/151306/53/background.png)
Operational procedures
41
857-164342 / Rev.C
Basic operations
Overview
This chapter presents a number of common procedures
frequently carried out on the EQ60 echo sounder.
Changing the echogram settings
To change the echogram settings:
1
Position the cursor in the Echogram field.
2
Click the right mouse button.
3
Observe the
Echogram
dialogue box.
4
Make the required changes.
Related topics
→
Echogram, page 81
Changing the range
To change the range:
1
Position the cursor in the Range field.
2
Click the right mouse button.
3
Observe the
Bottom Range
or
Surface Range
dialogue
box.
4
Make the required changes
or:
1
Place the cursor in the Range field.
2
Use the mouse wheel to change the range.
Related topics
→
Bottom Range, page 77
→
Surface Range, page 110
Changing the vertical resolution
The vertical resolution of the echogram increases with a shorter
pulse length.
For example, a pulse length of 1.024 millisecond gives a vertical
resolution of 19.2 cm, whereas a pulse length of 0.256
millisecond gives a vertical resolution of 4.8 cm. If the vertical
distance between two echoes is less than this, the two echoes
will be shown as one