Simrad EQ60 User Manual
Page 121
Instruction manual
109
857-164342 / Rev.C
Save Output Data - Check this box if you want to store
processed output data on the internal harddisk; position fixes,
bottom detections, annotations. This data are used by the
post-processing software when generating bottom contour maps.
Line No.
Enter the initial survey line number. A toggle button inside the
Status bar on the display controls the start and stop of each
survey line. The line number is automatically incremented (or
decremented) by one for every new survey line. Click the box
and local time will be used in the file names, otherwise GMT is
used.
Max File Size
Enter the maximum size of each replay file. The replay file
contains the unprocessed transceiver data. Several kilobytes of
sample data is written into this file every ping. All sample data
may be contained in just one file for short survey lines.
However, the amount of data grows rapidly as the survey lines
become longer, and it may be necessary to split the data into
fragments which are stored in sequential replay files.
Related topics
→
Operation, page 97
→
Replay, page 105
→
Playback and recording procedure, page 47
→
Size control, page 48