Quarterly, Biannually – Speed Queen Drying Tumblers SCB50EG User Manual
Page 60

58
M412616
Quarterly
6.
Remove screws holding rear drive guard to back
of tumbler.
7.
Inspect belts for wear and proper tension (refer to
Adjustments section).
8.
Reinstall rear drive guard to back of tumbler.
9.
Energize electrical circuit to tumbler by turning on
electrical disconnect switch on rear of tumbler.
10. Turn on gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be parallel with gas
supply line when in “ON” position.
1. Deactivate electrical circuit by turning off
disconnect switch on rear of tumbler.
2. Perform daily cleaning of accumulated lint.
3. Perform monthly inspection and cleaning of
accumulated lint.
4.
Clean accumulated lint and other debris from
front and back motor air vents.
5.
Shut off gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be at 90
0
angle to gas
supply line when in “OFF” position.
Biannually
1. Deactivate electrical circuit by turning off
disconnect switch on rear of tumbler.
2.
Perform daily cleaning of accumulated lint.
3.
Perform monthly inspection and cleaning of
accumulated lint.
4.
Perform quarterly inspection and cleaning of
accumulated lint.
5.
Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
6.
Shut off gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be at 90
0
angle to gas
supply line when in “OFF” position.
7.
Unlock and open service panel and inspect gas
connections for evidence of leakage or loose
connections.
NOTE: Spraying a mild solution of soap and water
on joints will cause bubbles to appear on any
leaking connections.
8.
Close and securely lock service panel.
9.
Open electrical junction box cover and inspect all
electrical and grounding connections for security.
Tighten any loose electrical connections.
10. Close electrical junction box cover and energize
electrical circuit to tumbler by turning on electrical
disconnect switch.
11. Turn on gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be parallel with gas
supply line when in “ON” position.
- Drying Tumblers JCB75CG Drying Tumblers SC75CSH Drying Tumblers SC50CG Drying Tumblers JCB30WE Drying Tumblers JCB30CSH Drying Tumblers JC50EG Drying Tumblers SC75CG Drying Tumblers JCB50CG Drying Tumblers SCB50CSH Drying Tumblers SCB30CSL Drying Tumblers JCB30CSL Drying Tumblers JCB30XG Drying Tumblers SC50CE Drying Tumblers JCB50CSH Drying Tumblers JCB75CE Drying Tumblers JC75CSH Drying Tumblers JCB30CG Drying Tumblers SCB30CE Drying Tumblers JCB50CE Drying Tumblers JCB30CE Drying Tumblers SCB30CG Drying Tumblers SCB75CG Drying Tumblers SC50EG Drying Tumblers JC75CG Drying Tumblers SC50CSH Drying Tumblers JC75CE Drying Tumblers SCB50CE Drying Tumblers SCB75CSH Drying Tumblers JC50CE Drying Tumblers JC50CSH Drying Tumblers SCB75CE Drying Tumblers SCB30XG Drying Tumblers JC50CG Drying Tumblers SC75CE Drying Tumblers JCB75CSH Drying Tumblers SCB50CG Drying Tumblers JCB50EG Drying Tumblers SCB30WE