beautypg.com

1 scsi cabling, 1 cable lengths, Table29 controller module a (3x15) – Sun Microsystems Sun StorEdge A3500 User Manual

Page 37: Table210 controller module b (3x15), Table211 controller module c (3x15), Scsi cabling

background image

Chapter 2

StorEdge A3500 Configurations

2-21

2.5.1

SCSI Cabling

2.5.1.1

Cable Lengths

The following tables show the lengths of each SCSI cable connected to the drive
connections on the respective controller modules.

The inboard IN/OUT connectors on each of the disk arrays are connected together
using a 0.2m SCSI jumper cable, part number 530-1883-xx.

TABLE 2-9

Controller Module A (3x15)

SCSI Port Number

Cable Length

Part Number

1

.8m

530-1884-xx

2

.8m

530-1884-xx

3

4m

530-2352-xx

4

4m

530-2352-xx

5

4m

530-2352-xx

TABLE 2-10

Controller Module B (3x15)

SCSI Port Number

Cable Length

Part Number

1

.8m

530-1884-xx

2

.8m

530-1884-xx

3

2m

530-1885-xx

4

2m

530-1885-xx

5

2m

530-1885-xx

TABLE 2-11

Controller Module C (3x15)

SCSI Port Number

Cable Length

Part Number

1

.8m

530-1884-xx

2

.8m

530-1884-xx

3

2m

530-1885-xx

4

2m

530-1885-xx

5

2m

530-1885-xx