Page 24
2-8
Sun StorEdge A3500 Hardware Configuration Guide • September 1998
2.1.3.2
Module ID Switch
Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to
Facing the front of the expansion cabinet:
■
controller module A controls the right side of disk arrays 1 through 3 and all of
disk arrays 4 and 5.
■
controller module B controls the left side of disk arrays 1 through 3 and all of disk
arrays 6 and 7.
This configuration is shown in
2.1.3.3
SCSI Jumper Cables and Terminators
The top four disk arrays should have SCSI jumper cables between the middle SCSI
connectors (IN/OUT-1 and IN/OUT-2) and a differential SCSI terminator in the far
right SCSI connector (IN/OUT-2).
The bottom three disk arrays should have differential SCSI terminators on the inside
IN/OUT-1 and IN/OUT-2 SCSI connectors. This configuration is shown in
.
TABLE 2-2
2x7 Module ID Switch Settings
Disk array number
Module ID setting
7 (Top)
5
6
4
5
5
4
4
3
3
2
2
1 (Bottom)
1