F100 sm - subnet mask, F100 sm – subnet mask, For example, enter – Symmetricom XLi IEEE 1588 User Manual
Page 91: Xli responds, The xli responds (example), F100 ipsm

XLi IEEE 1588 Clock
83
997-01510-03, Rev. C, 12/12/2006
2
5
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
For example, enter:
F100 IP 206.54.0.21
XLi responds:
OK
RESETING THE UNIT
PLEASE WAIT…
To obtain the IP address of the unit Standard network port, enter:
F100 IP
The XLi responds (example):
F100 IP 206.54.0.21
The three commands, F100 IP, F100 SM, and F100 G, can be concatenated to set all three values
simultaneously. To do so use the following format:
F100IPSMG
Note:
The three commands (i.e., IP, SM, G) can be used in any order relative to each other. A colon
separator “:” can be used instead of following IP, SM, and G (e.g.,
IP:192.168.46.150
)
For example, using appropriate values for your network, enter something similar to:
F100 IP 192.169.46.150 SM:255.255.255.0 G 192.168.46.1
XLi responds:
OK
RESETING THE UNIT
PLEASE WAIT…
F100 SM – Subnet Mask
Note:
F100 SM can be used concurrently with F100 IP and F100 G. See the last example provided in
the
section, directly above this one.
Use function F100 SM to display or configure the Subnet Mask. To set the Subnet Mask and restart the
unit, enter:
F100SM