beautypg.com

F100 sm - subnet mask, F100 sm – subnet mask, For example, enter – Symmetricom XLi IEEE 1588 User Manual

Page 91: Xli responds, The xli responds (example), F100 ipsm

background image

XLi IEEE 1588 Clock

83

997-01510-03, Rev. C, 12/12/2006

2

5

1

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

For example, enter:

F100 IP 206.54.0.21

XLi responds:

OK

RESETING THE UNIT

PLEASE WAIT…

To obtain the IP address of the unit Standard network port, enter:

F100 IP

The XLi responds (example):

F100 IP 206.54.0.21

The three commands, F100 IP, F100 SM, and F100 G, can be concatenated to set all three values
simultaneously. To do so use the following format:

F100IPSMG

Note:

The three commands (i.e., IP, SM, G) can be used in any order relative to each other. A colon

separator “:” can be used instead of following IP, SM, and G (e.g.,

IP:192.168.46.150

)

For example, using appropriate values for your network, enter something similar to:

F100 IP 192.169.46.150 SM:255.255.255.0 G 192.168.46.1

XLi responds:

OK

RESETING THE UNIT

PLEASE WAIT…

F100 SM – Subnet Mask

Note:

F100 SM can be used concurrently with F100 IP and F100 G. See the last example provided in

the

F100 IP – IP Address

section, directly above this one.

Use function F100 SM to display or configure the Subnet Mask. To set the Subnet Mask and restart the
unit, enter:

F100SM