F11 DDDDHHHMMMSSSmmmQ

With the new formatting, F8 displays:

128D16H41M27*

And F9 displays:

365D16H45M22S680*

F13 – Time Error

Use function F13 to request the estimated worst-case time error due to oscillator drift during periods of
unlock from a reference source. See “System Time & Frequency Accuracy” on page 10 for more
information on time error for different reference sources. Time error begins to accumulate when the
receiver loses lock to a reference source. The XLi calculates the worst-case time error based on the
stability of system clock’s oscillator type, and the time elapsed since loss of lock.

Command Line

The Command line interface will report time error when it receives the following string:

F13

The XLi responds:

F13

where:

For example, to display the time error, enter:

F13

XLi responds (example):

F13 TIME ERROR -0.002932863

F13

= ASCII string for function F13

= ASCII

space

character

= calculated worst-case error in seconds

= carriage return character

= line