Response (one of the following lines):

OK - The PTP Option Card has been initialized to user entered values

Configuring the PTP Reference Clock Settings

To review the PTP reference clock configuration settings with respect to Master/Slave and reference
clock Primary/Secondary/Standby settings, use the following format:

F131 B C

For example, enter:

F131 B4 C

Response (example):

F131 B4 C SLAVE PRI

To change the settings, use the following format:

F131 BC

where:

For example, enter:

F131 B4 C SLAVE PRI

Response (one of the following lines):

OK - Ref Clock Configuration has been received and applied by the PTP Option Card

Note:

The PTP reference clock configuration settings are saved in XLi NVRAM so they can be used to

initialize the PTP option card with Master/Slave and Pri/Sec/Stby selections at XLi power-up.

F

= ASCII character F

131

= unit function number

= space

B

= ASCII letter to denote Option Bay number follows

= Option Bay Number, 1 through 4.

C

= specify PTP Configuration command

= MASTER or SLAVE (Factory Default is MASTER)

= PRI, SEC or STBY, which must be entered if the is SLAVE.

If the is MASTER, this field is not applicable.