Response (one of the following lines):
OK - The PTP Option Card has been initialized to user entered values
Configuring the PTP Reference Clock Settings
To review the PTP reference clock configuration settings with respect to Master/Slave and reference
clock Primary/Secondary/Standby settings, use the following format:
F131 B
For example, enter:
F131 B4 C
Response (example):
F131 B4 C SLAVE PRI
To change the settings, use the following format:
F131 B
where:
For example, enter:
F131 B4 C SLAVE PRI
Response (one of the following lines):
OK - Ref Clock Configuration has been received and applied by the PTP Option Card
Note:
The PTP reference clock configuration settings are saved in XLi NVRAM so they can be used to
initialize the PTP option card with Master/Slave and Pri/Sec/Stby selections at XLi power-up.
F
= ASCII character F
131
= unit function number
= space
B
= ASCII letter to denote Option Bay number follows
= Option Bay Number, 1 through 4.
C
= specify PTP Configuration command
= MASTER or SLAVE (Factory Default is MASTER)