The format of the f8 output string, Soh>ddd:hh:mm:ssq Page 55
Page 55

XLi IEEE 1588 Clock
47
997-01510-03, Rev. C, 12/12/2006
2
5
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
•
F5 – Time-Quality Setup (page 43)
•
F11 - Time Output Format (page 50)
•
The Format of the F8 Output String
The factory setting for the output string format is as follows:
where:
The time quality character, "Q", is one of the following characters:
The time quality characters can not be modified.
F11 - Time Output Format (page 50)
to change the format of the F8 output string.
F5 – Time-Quality Setup (page 43)
to set the four time quality thresholds.
= ASCII Start-of-Heading character
= ASCII Carriage Return character
= ASCII Line Feed character
DDD
= day-of-year.
HH
= hours.
MM
= minutes.
SS
= seconds.
mmm
= milliseconds.
:
= colon
separator.
Q
= time quality character (see the following table)
SPACE = Time error is less than time quality flag 1's threshold
.
= Time error has exceeded time quality flag 1's threshold
*
= Time error has exceeded time quality flag 2's threshold
#
= Time error has exceeded time quality flag 3's threshold
?
= Time error has exceeded time quality flag 4's threshold
or a reference source is unavailable