SUPER MICRO Computer H8QI6-F User Manual
Page 56
4-4
H8QI6/i-F Serverboard User’s Manual
PIO Mode
PIO (Programmable I/O) mode programs timing cycles between the IDE
drive and the programmable IDE controller. As the PIO mode increases, the
cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4. Select Auto to
allow BIOS to auto detect the PIO mode. Use this value if the IDE disk drive
support cannot be determined. Select 0 to allow BIOS to use PIO mode 0,
which has a data transfer rate of 3.3 MBs. Select 1 to allow BIOS to use PIO
mode 1, which has a data transfer rate of 5.2 MBs. Select 2 to allow BIOS
to use PIO mode 2, which has a data transfer rate of 8.3 MBs. Select 3 to
allow BIOS to use PIO mode 3, which has a data transfer rate of 11.1 MBs.
Select 4 to allow BIOS to use PIO mode 4, which has a data transfer rate of
16.6 MBs. This setting generally works with all hard disk drives manufactured
after 1999. For other disk drives, such as IDE CD-ROM drives, check the
specifi cations of the drive.
DMA Mode
Selects the DMA Mode. Options are Auto, SWDMA0, SWDMA1, SWDMA2,
MWDMA0. MDWDMA1, MWDMA2, UDMA0. UDMA1, UDMA2, UDMA3,
UDMA4 and UDMA5. (SWDMA=Single Word DMA, MWDMA=Multi Word
DMA, UDMA=UltraDMA.)
S.M.A.R.T.
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict
impending drive failures. Select "Auto" to allow BIOS to auto detect hard
disk drive support. Select "Disabled" to prevent AMI BIOS from using the
S.M.A.R.T. Select "Enabled" to allow AMI BIOS to use the S.M.A.R.T. to sup-
port hard drive disk. The options are Disabled, Enabled, and Auto.
32-Bit Data Transfer
Select "Enabled" to activate the function of 32-Bit data transfer. Select "Dis-
abled" to deactivate the function. The options are Enabled and Disabled.
Hard Disk Write Protect
Use this setting to Enable or Disable hard disk write protection for your system.
This is effective only if the device is accessed through the BIOS.
IDE Detect Timeout (Sec)
Use the +/- keys to adjust and select the time out for detecting ATA/ATAPI de-
vices. The default value is 35.