beautypg.com

Installing the appliance, 1 electrical connection, Instructions for the installer – Smeg A2PY-6 User Manual

Page 4

background image

Instructions for the Installer

2. INSTALLING THE APPLIANCE

It is the law that all gas appliances are installed by

competent persons.

Corgi gas installers are approved to work to safe and satisfactory

standards. All gas installation, servicing and repair work must be in

accordance with the gas safety regulations 1984 (installation and use) as

amended 1990.

It may be installed against walls one of which is higher than the worktop

surface, at least 50 mm from the side of the appliance, as shown in the

installation class drawings A and B. Wall units or extractor hoods installed

above the appliance's work-top must be at least 750 mm above it.

A

B

Built-in Appliance

Free-Standing Installation

2.1 Electrical connection

Check that the voltage and size of the power supply line are as specified
on the nameplate inside the storage compartment.
This nameplate must never be removed.

The plug on the end of the power supply cable and the wall socket must
be of the same type (in compliance with the relevant national standards).
Check that the power supply line is properly earthed. The use of
reductions, adapters or junctions is not recommended.

The appliance's power supply line must be fitted with an omnipolar
breaking device with contact gap of at least 3 mm, located in an easily
accessible position close to the appliance itself.

45