beautypg.com

Troubleshooting – Southbend 14" METAL CUTTING BANDSAW SB1022 User Manual

Page 40

background image

TROUBLESHOOTING

-38-

For Machines Mfg. Since 8/09

Model SB1021/SB1022

T R O U B L E S H O O T I N G

If you need replacement parts, or if you are unsure how to do any of the solutions given here, feel free
to call us at (360) 734-1540.

Symptom

Possible Cause

Possible Solution

Machine does not
start.

1. Power supply switched off/has

incorrect voltage.

1. Switch power supply on/verify voltage.

2. Blown fuse/tripped circuit breaker

at main panel.

2. Correct the cause of overload, then reset/replace

fuse or breaker.

3. Plug or receptacle is corroded or

mis-wired.

3. Clean/retighten contacts; correct the wiring.

4. Thermal overload relay has tripped.

4. Allow relay/motor to cool. If necessary, press reset

button inside switch.

5. Break or short in wiring; or loose

connections.

5. Trace/replace broken or corroded wires; fix loose

connections.

6. Motor ON/OFF switch at fault.

6. Replace switch.

7. Motor connection wired incorrectly.

7. Wire motor correctly (refer to inside junction box

cover or manual).

8. Start capacitor blown or at fault.

8. Replace start capacitor.

9. Contactor not energized/has poor

contacts.

9. Test all legs for power, test field coil and replace if

at fault.

10. Centrifugal switch at fault.

10. Adjust/replace centrifugal switch.

11. Motor at fault.

11. Test for shorted windings, bad bearings and repair

or replace.

Machine has
excessive vibration
or noise.

1. Motor fan rubbing on fan cover.

1. Fix/replace fan cover; replace loose or damaged fan.

2. Motor or table is loose.

2. Tighten any loose fasteners.

3. V-belt(s) loose.

3. Tighten V-belt(s).

4. Guide post lock lever is loose.

4. Tighten the lock lever.

5. Machine incorrectly mounted on

floor.

5. Level/shim base; tighten/adjust mounting hardware

or feet.

6. V-belt(s) worn or damaged.

6. Replace V-belt(s). Use link belts if possible.

7. Pulley loose or not in alignment;

shaft bent.

7. Replace worn pulley, key, and shaft, and realign.

8. Centrifugal switch out of

adjustment; at fault (SB1021 only)

8. Adjust/replace centrifugal switch.

9. Motor bearings worn or damaged.

9. Replace motor bearings or replace motor.

10. Phase converter (if used) wild wire

incorrectly connected (SB1022
only).

10. Connect wild wire to correct leg (must avoid

transformer or sensitive electronics).

Main motor
chatters during
startup or during
operation.

1. Extension cord (if used) is causing

voltage drop.

1. Move machine closer to the power source or use a

larger gauge or shorter extension cord.

2. Phase converter (if used) wild wire

connected wrong.

2. Connect wild wire to the machine power supply

terminal that is not part of the contactor field coil
power supply circuit.

3. Power supply has incorrect voltage

on one or more legs.

3. Contact your power company to fix the power

supply.

Machine operates
in reverse.

1. Power connections wired out of

phase (SB1022 only).

1. Swap two power incoming power leads (see Page

47).

Troubleshooting

This manual is related to the following products: