beautypg.com

Siemens Albatros Zone Controler CE1U2353en01a User Manual

Page 10

background image

10/26

Siemens Schweiz AG

User Manual OEM

CE1U2353en01a

HVAC Products

Overview of OEM settings 22.

November

2006

Operating line

User level

Function

Default value

Minimum

Max

Unit

DHW storage tank
5010 O Charging

Once/day ¦ Several times/day

Several times / day

5020 F Increase of the flow temperature setpoint

16

0

30

°C

5022 F Type of charging

With B3 ¦ With B3/B31 ¦ With B3, legio B3/B31

With B3/B31

5024 O Switching

diff

5

0

20

°C

5030 O Charging

time

limitation

150

− − − / 10

600

min

5040 O Discharging

protection

Off ¦ Always ¦ Automatically

Automatic

5050 F Charging temp max

80

8

BZ 5051 OEM

°C

5051 O Storage tank temp max

90

8

95

°C

5055 F Recooling

temp

60

8 95 °C

5056 F Recooling heat gen/HCs

Off ¦ On

Off

-

5057 F Recooling

collector

Off ¦ Summer ¦ Always

Off

-

5060 F Electric immersion heater:operating mode

Substitute ¦ Summer ¦ Always

Substitute

-

5061 F Electric immersion heater:release

24h/day ¦ DHW release¦ Time program4/ DHW

DHW release

-

5062 F El

immersion

heater

control

External thermostat ¦ DHW sensor

DHW sensor

-

5070 O Automatic

push

Off ¦ On

On

5085 F Excess heat draw

Off ¦ On

On

-

5092 F With prim contr/system pump

No ¦ Yes

No

5093 F With solar integration

No ¦ Yes

Yes

Configuration
5710 I

Heating circuit 1

Off ¦ On

On

-

5715 I

Heating circuit 2

Off ¦ On

On

-

5730 I

DHW sensor B3

Sensor ¦ Thermostat

Sensors

-

5731 I

DHW controlling element Q3

None ¦ Charging pump ¦ Diverting valve

charging pump

-

5890 I Relay

output

QX1

None ¦ Circulating pump Q4 ¦ El imm heater DHW K6 ¦
Collector pump Q5 ¦ H1 pump Q15 ¦ Alarm output K10 ¦
2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2 Q22
¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump HCP
Q20 ¦ H2 pump ¦ Q18 primary pump Q14

None

-

5930 I Sensor

input

BX1

None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW
circulation sensor B39

None

-

5931 I Sensor

input

BX2

None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW
circulation sensor B39

None

-