beautypg.com

Chapter 6 ac electrical characteristics, 1 serial management interface (smi) timing, Figure 6.1 smi timing diagram – SMSC FlexPWR LAN8710i User Manual

Page 55: Table 6.1 smi timing values, Chapter 6, Ac electrical characteristics, Serial management interface (smi) timing, Section 6.1, "serial management

background image

MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR

®

Technology in a Small Footprint

Datasheet

SMSC LAN8710/LAN8710i

55

Revision 1.0 (04-15-09)

DATASHEET

Chapter 6 AC Electrical Characteristics

The timing diagrams and limits in this section define the requirements placed on the external signals
of the Phy.

6.1

Serial Management Interface (SMI) Timing

The Serial Management Interface is used for status and control as described in

Section 4.14

.

Figure 6.1 SMI Timing Diagram

Table 6.1 SMI Timing Values

PARAMETER

DESCRIPTION

MIN

TYP

MAX

UNITS

NOTES

T1.1

MDC minimum cycle time

400

ns

T1.2

MDC to MDIO (Read from PHY)
delay

0

30

ns

T1.3

MDIO (Write to PHY) to MDC setup

10

ns

T1.4

MDIO (Write to PHY) to MDC hold

10

ns

Clock -

MDC

Data Out -

MDIO

T

1.2

Valid Data

(Read from PHY)

T

1.1

T

1.3

T

1.4

Data In -

MDIO

Valid Data

(Write to PHY)

This manual is related to the following products: